#1 Trying to fix a inop kitchen outlet in a 30 yr old mobile home. Attaching the Wires to the Outlet. ** NOT AN ELECTRICAL** but engineer nonetheless. How do you spot these conditions? In several instances such as this a bad connection is found where the neutral wire pushes into the back side of the outlet. There is a process of elimination here that needs to be followed and wild conjecture isn't going to help anything. So the ground wire is like a long test lead back to the source voltage. Google phantom voltage on 3-way . In fact, hot-ground is equal to the sum of the hot-neutral and neutral-ground voltages. I was reading 30 Volts and couldn't get what was a previous working light to work. There are about 5 or 6 receptacles in 2 rooms that all stopped working at once. If any of the wires look corroded, strip them until you see shiny copper and clean the connections. Circuit breaker is 15a and also connects to 3 light switches controlling 6 light fixtures total. You can reverse the probes and for real voltage, get the same reading. Specifications. https://my.fluke.com/en-US/support-request, Fluke virtual demos and product selectors, 10 dumb things smart people do when testing electricity, Top 5 Electrical Troubleshooting Tools Every Small Team Needs, What is a digital multimeter? If hot-neutral voltage, measured with load on the circuit, is greater than hot-ground, then the neutral and ground are switched. I did verify when all these 3 wires are disconnected that: black is hot when switch is on, white and ground has no electricity. When light switch is off, I get like 2 volts to garage door opener outlet. Welcome to ElectriciansForums.net - The American Electrical Advice Forum. leakage current is still there as wasted electricity. When you look at intermediate sockets in the circuit, commonly a pair of wires carries power to the socket and another pair carries the power to the next socket in the chain. To learn more, see our tips on writing great answers. Is your panel labeled? New blog post from our CEO Prashanth: Community is the future of AI, Improving the copy in the close modal and post notices - 2023 edition. Easy-to-wire terminals accept 10 - 4 AWG conductors, flush-mount devices fit two-gang outlet boxes. fix a problem within an hour of the call because it was on the way to the place I was Can I supply my central heating (programmer, two port valves and boiler) via a fused spur taken from the immersion heater circuit? Since you said that the nearest receptacle is at 120V, I'm assuming that it's on the same circuit and the next wired in sequence? Well help you select the right product for your needs. What do I look for? Thank You. I looked up at the light switch and gave her a flip and nothing. I had something similar happen. Background: Paul, a Student from Bremerton, Washington. Attached it; problem solved. Next, tape, twist, and wrap one end of the old wire with an end of your new wire. So I tried: pulling out the outlet from the wall and confirmed that 30V is actually coming from the wires to the outlet (so it's not a faulty outlet). NOTE: Grounding was ignored in the above discussion, bare wire goes to green screw ground lug, wire nut with pigtail is handy for this. What sort of contractor retrofits kitchen exhaust ducts in the US? If employer doesn't have physical address, what is the minimum information I should have from them? By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Anyone have any ideas what could be going on? Estimated Time: Depends on personal level experience, ability to work with hand tools and electrical troubleshooting skills. Are the neutral and ground (green) wires reversed or shorted? Keep in mind that i did not even work on this switch.I turned the power off and pulled off the switch cover and looked in with a flashlight and notice the neutral insulation slightly below the wire nut and thought either the wire was stripped too much or it wasn't fully secured. If the problem is due to the push-in type wire connection then replace the outlet and make a new splice. The best answers are voted up and rise to the top, Not the answer you're looking for? Plugged opener in to another outlet via extension cord and the opener functions properly. In fact, it's wired exactly the same way as your 15- or 20-amp home outlets are, albeit with heavier 10-gauge wire, instead of 14- or 12-gauge wiring. Unlike AC, if the polarity is reversed DC gives a reading of 0 so I would see inconsistent readings depending on how I was hooking up the leads. (Tenured faculty), PyQGIS: run two native processing tools in a for loop. Hi John, First, I have to apologize for the following really long description. Power at Ceiling fan reading 30 volts instead of 120 volts Hello, My ceiling fan and light have been installed for a couple years and the fan and light both stopped working recently. There is obviously some potential there or the LEDs wouldnt light. How can I figure out why this electrical receptacle is dead? Tools Required: Basic Electricians Pouch Hand Tools and Voltage Testers and Meters. If you need to plug in at a location where there is no 30 amp RV style outlet you can buy an adaptor at any RV dealer that will adapt your 30 amp RV plug to a standard 15 or 20 amp duplex receptacle. I have the white neutral wire hooked up to the outlet. have a GFI outlet. I believe what they are saying is that this SWITCH should completely detatch the load from receiving any power because the switch can run off of the energy being routed from the line to the neutral (which is required). Incorrectly wired receptacles are not uncommon. There likely isnt anything wrong with your meter is that test indicates the same voltage both ways. @MatthewLevine Flip the breaker for that circuit and then go around testing each outlet nearby to see which don't have power anymore. I replaced the light fixture there myself about 1 month ago and there are 3 standard wires, black, white, ground. If with the circuit breaker on, the same amount of items are are lacking power as were unpowered when the circuit breaker was off, you have an open connection in the wiring leading to the first socket in the daisy chain, or the incoming connection to the first socket is bad. Thanks everyone for the ongoing conversation on this issue. I am assuming it is an electric or it would likely be a 30A circuit and outlet. I get 30 volts when measuring neutral to ground, I get 60 volts when I measure neutral to live, and I get 120 volts when I measure from live to ground. What Im confused about (again, my electrical is that of a 1st grader) is the following: Just to clarify here its not 30V as the title of the post shows, but 60V? To subscribe to this RSS feed, copy and paste this URL into your RSS reader. New information (both scenarios have the switch off): So, not sure why I only get a reading with the circuit off when the leads are backward. I plan on trying to reset all of my breakers again to make sure I did it properly and with enough force. Discovered the second socket's neutral wire had become disconnected during installation of the plug. This will require proper repairs and in many cases replacing an outlet that may be affected due to a burnt wire connection. Given that, are you saying that it's possible there's another breaker that might need to be reset? Once these prongs are connected, the readout on the multimeter will display the potential voltage at the breaker position. It only takes a minute to sign up. I need to do an apples to apples comparison to get some of the answers that will make more sense. Find our what all has been switched off and that'll be your circuit. I tested a switch with a resistive load and saw almost no leakage and it wasnt DC, which is pointing to the DC being caused by the connected load. How do two equations multiply left by left equals right by right? Each hot should go to a pole on the breaker panel - this should by code be a 2 pole breaker. A wire stripping tool used to safely strip electrical wires. This handy tool has multiple uses: On the other hand, sensitive electronic loads such as computer equipment and instrumentation do care about a clean ground (a ground with no voltage and no-load currents on it). It was really frustrating when the light didn't originally work as everything has been perfect till I took it apart. Is the outlet wired correctly? Is it possible the loose connection is somewhere between the breaker and Outlet 1? K KeepItSimpleStupid Joined Mar 4, 2014 5,088 Oct 3, 2017 #3 The most common mis-wiring occurs if hot and neutral are switched, or if neutral and ground are either switched or shorted. A 20-amp circuit, protected by a 20-amp breaker or fuse, must be served by 12-gauge or 10-gauge wire. I just replaced a broken light fixture in my closet. If you say the fixture doesn't work even though the old one did, perhaps a connection came loose somewhere and now you have an open circuit with only the phantom voltage. Heavy-duty nylon body and cover for outstanding resistance to impact and harsh chemicals. Here are my findings. 1. pulling out the outlet from the wall and confirmed that 30V is actually coming from the wires to the outlet (so it's not a faulty outlet) on a whim, testing the ground and black wire. But if you have any other ideas on how to resolve it (even it if it's "call a pro") that would be excellent, @MatthewLevine: Circuit breakers are designed with a mechanism which is cocked by moving the handle to "off" and released when an overload occurs, so a breaker can trip even if the handle is held in the "on" position; the handle will spring to the "tripped" position if it can, but the circuit will disconnect regardless. Pull the wire stripper toward the end of the cable to cut through the outer coating and expose the wires inside. About 6 months ago, I replaced the receptacle in this outlet with new one (I actually did for all outlets inside the house, except garage), and did verify that it works properly with a receptacle tester. The best answers are voted up and rise to the top, Not the answer you're looking for? @MatthewLevine: I'd suggest overloading the outlet again to trip a breaker and find out which breaker tripped, and whether the failure to trip the mate was a one-time thing or represents consistent behavior. The thread also mentions that the switch may behave differently in 3-way mode so I am going to check that out as well. Most likely the next one in sequence would be the one physically closest, but you'll again have to revert back to my answer of testing each outlet down the line. The switch uses a relay. Installation Manual PDF. Clamp a wire stripper around the outlet end of the 10/4 cable so it's 1 foot (30 cm) from the end. Connect and share knowledge within a single location that is structured and easy to search. Hot-neutral is the load voltage. I appreciated his concern and asked if I was right to be concerned at the voltage readings I was getting. Do you think the loose connection would generate enough heat to be found with a laser temperature gun? via immersion heater circuit? And how to capitalize on that? I have not shut tge electricity off to the wires, they were live. What PHILOSOPHERS understand for intelligence? It is generally used to connect two devices together, which are generally incompatible in their physical forms. When I test with one probe in the outlet and one on the ground it reads 122- 124 volts. Be sure to make a good splice and use the correct size wire connectors approved for the number of wires, and the gauge of the wires. Being that I have zero electrical background, would someone be able to summarize this for me so I can give a simplified version to the manufacturer? Also that you are not dealing with aluminum wiring. When replacing the light fixture I noticed that there is only 30 V AC between the white and black wires. How Do You Tell If You Have Low Voltage at an Outlet? I am not sure of code if a dryer needs it's own 120V run to provide it. The first thing I would do is take your multimeter and go to another fixture and make sure you see 120VAC on it - just to make sure the meter works correctly (assuming you are in a 120VAC country). Some key points to clarify based on some comments on the thread: Try an incandescent bulb in the lamp. after I hung up, I get a call from a supervisor who wanted more info than the CSR had gotten and wanted specifics i.e., time, location, which outlets I tetsted, etc. If there is a transformer supplying power to the panel then the transformer may need to be tapped differently to provide more voltage. Making statements based on opinion; back them up with references or personal experience. Looking for any ideas here, still actively troubleshooting this issue. After changing out all the receptacles with tamper resistant ones I was getting 120v from line to ground, 20v neutral to ground and 95v neutral to hot. Making statements based on opinion; back them up with references or personal experience. Kohree 30 Amp RV Power Outlet Box, 125 Volt Enclosed Lockable Nema TT-30R RV Outdoor Electrical Receptacle Panel, Weatherproof Plug for Temporary Hookup RV Camper Travel Trailer . @MatthewLevine For fixing the wire, your best bet would be to find both ends of the wire (at your current receptacle and the one upstream of it) and disconnect them from their outlets. I checked the breakers and reset each one and even took off the outlet cover and hooked the volt meter up to the wires and it still reports 13 volts. This is the first outlet in the circuit I believe. There is a switch in the room that controls an outlet. A multimeter can let you know if the range is less than 120, which is the expected voltage in a home's electric wall outlet. Replaced circuit breaker no change, moved circuit breaker to a new location on the bus, no change. This problem can occur in rooms where high consuming electrical devices are used such as portable heaters, portable air conditioners and vacuum cleaners. At these outlets: One small update: I plug a different power strip into the outlet and the voltage measurements are identical as if no power strip is plugged in. Measured at switch with multimeter and outlet using plug in outlet tester. Considering it's getting 13v even on going hot to ground, maybe that means the hot wire melted somewhere (?). Wasted energy, wear and tear on major appliances, and potential fire hazards all of these can happen if you have a problem with the voltage at an outlet in your home. Hey all Ive passed this onto the manufacturer to get an official answer. When use separately, the maximum output of the Type C port is 3.0 Amp 5V DC, and the Type A port is 2.4 Amp 5V DC .Compatible with all kinds of USB devices with multiple . OK, I discovered something today that doesnt make sense to me, but it does explain some of what I have been seeing. The outlet appears to have 3 wires, I'm guessing the neutral, the ground and the hot wire. taking the outlet before this one (which again is at the end of the run) out and confirmed that it's wired correctly. That's because your 30-amp RV outlet needs one neutral, one hot and one ground wire to be connected properly, as shown in this diagram. Why do I see only 50 volts on my live wires? I have a circuit with a switch and 3 outlets. The problem might be at the first receptacle that is faulty, it might also be at the last one that works. By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. The electrical circuit load of these high consuming devices is placed on and through every splice or connection within the circuit. (The switch in the light fixture broke when I pulled too hard on the chain.). Id like to see something technical from Inovelli about this because the switch uses a relay so it should be capable of fully turning the power on and off. Put someone on the same pedestal as another, 12 gauge wire for AC cooling unit that has as 30amp startup but runs on less than 10amp pull. It appears that the outlet circuit may have lost connection with the neutral, so the circuit wiring and connections will need to be examined to identify the problem. Itappened again today so I decided to take a voltmeter to to all three outlets to look for clues. Garage door opener stopped working one day. I replaced all the sockets in a house because they'd used cheap sockets and daisy chained them through the pushin connections. Hi Cory, Hopefully you will find the bad connection right at the panel but if it is more involved, I strongly recommend doing that rather than looking for voltage with the circuit live. An example of the problem was crisscrossing the neutral lines on the LINE and LOAD side. Installed a new ceiling fan, with no previous light or power. This list of articles will help you learn about the features and benefits provided by GFI and GFCI Receptacles and how they are wired. The strange things is, all 120 volt outlets work according to the listin. The contractors added a grounding system and installed GFCI outlets in the kitchen and bathrooms, but the rest of the receptacles in the house are still only two wire systems with no ground. Review invitation of an article that overly cites me and the journal. Electrical Question #1: Why Do I Have 70 Volts on a 120 Volt Receptacle? Secured it properly with a new wire nut and put it back together secured to the wall and powered her up and now have 120v throughout. I can talk to you about the 4Ps of marketing if you want in exchange? Keep the wires separated and safe and then flip the breaker back on. I could understand it with a dimmer, especially in a non-neutral application. Regarding the reading, I suspect the variance from end to end has more to do with two different meters. I appreciate the help. Why would an 'off' traveler have voltage on it? Switch off: If I measure with the polarity switched on the meter (black to load, red to ground) the meter reads 60 volts. Why hasn't the Attorney General investigated Justice Thomas? That this is American wiring per NEC. This might fix your issue. Dont be alarmed: Highly inductive loads can also cause a minor voltage draw. Learn more about Stack Overflow the company, and our products. I have three AC outlets on one breaker that seem to stop working some mornings randomly. In what context did Garak (ST:DS9) speak of a lie between two truths? Application: Troubleshooting Receptacle Outlets that do not work, or do not have full power. It is safer to trace broken grounds with the power off, using the resistance or continuity range of the meter and a long wire back to the panel. The wall mounted airconditioning was on the living room circuit, problems became apparent similar to the OPs question. My confusion throughout stemmed from the fact that I was measuring DC using the AC setting on my meter (I had no idea would actually work). Which is why double-ups on circuit breakers is prohibited under NEC among other things. To check if neutral and ground are switched, measure hot-neutral and hot-ground under load. If it's still 13V, then the problem is upstream of this between the walls or at another receptacle along the line. Traditionally, voltage drop means an expected or normal dip in an electrical circuit in a home. Problem with Outlet Receptacle This generator was advertised as only putting out 120 volts on the 240 volt outlet. Feel the box for excessive heat and sniff the air for the smell of burnt wiring or plastic. Boiler, programmer etc. This is a typical indication that a splice or connection to the neutral has been lost. Pay close attention to the neutral connections that may be made to the outlet or check any neutral wire splices. At the switch, I am measuring 0v when off (load to ground, load to neutral, neutral to ground - all 0v). Check the voltage between the hot and neutral. I've seen double-ups in neutral bus bars come loose. They should be banned IMO. Possibly, when wiring the new light fixture, something went wrong, but the light works so I did not pay attention until the outlet cannot feed my Xmas lights. There's no need to split breakers on a 30 amp panel because there is only L1 and 120 volts present. Shop Utilitech. Also, what does the outlet show when you test in AC? Keep in mind that theres also a language barrier that needs to be translated. Is it a bad ground somewhere perhaps?? Current electrical codes require that multi-wire branch circuits must be powered by a pair of breakers that are interlocked so that whenever either one is turned off or tripped the other will likewise be disconnected, but some installations lack that interlock. Ive got the same thing happening with a 50W LED flood light, not 50W equivalent, 50W actual. But the light bulb won't turn on because there is only 30 V. (Even if I disconnect the light fixture completely there is still only 30 V. It seems to me that it must be a problem with the wiring. Asking for help, clarification, or responding to other answers. Of course, if you suspect a wiring fault, then you should consult with a licensed electrician. I really hope it's not a melted wire because I have no clue how one would fix that if it's in the middle of the wall. 30 amp, 250 volt, 6-30R, 2-pole, 3-wire. Simply attach your 15-amp rated devices plugs into the transparent female end of the adapter and plug the 30-amp locking male end into the generator. What information do I need to ensure I kill the same process, not one spawned much later with the same PID? Edit: Adding details to make it easier for anyone new to the thread. When the switch is on I get a reading either way I connect (red to load, black to ground or red to ground, black to load). When Wall Outlets and Receptacles Do Not Work, or They Do Not Have Full Power and the Voltage is Not Normal: Home electrical wiring includes 110 volt outlets and 220 volt outlets and receptacles which are common place in every home. $3686. So if the switch is leaking, why isnt there voltage at the load? However, the voltage drop should not be severe (3.5 or fewer volts of drop at the point of use for a 120-volt distribution panel is about as high as you would want to go). The black power feed hot goes to the white of the switch leg (ideally there should be a black tape marking this as hot) and the switched hot returns, goes through the lamp and back towards the panel via the white neutral. Makes for good feelings, eh? The microwave is constantly plugged in and has a LED display that never turns on when the circuit isnt working. can one turn left and right at a red light with dual lane turns? With a standard switch I am getting 120v on, 0v off as expected. I have a string of LED lights plugged into a receptacle controlled by a LZW30-SN, and mine turn off fully. if the outlet was wired using the stabs (wires pushed in) not screwed in the connection of the hot side probably melted or you would have 120 from hot to the ground. Dave, Wire a Dryer with a 3 Prong Cord or 4 Prong Cord, UK Government Planning Department for Communities. The Unit Uses An Illuminated Red Led In The Center Of The Meter And Emits Audible Tones To Notify When Voltage Is Above 30 Volts . Turn off the power to this circuit and then remove this outlet and inspect the wiring connections. The plugs are all on the eves of my house, so I am just waiting for the weekend to pull the plug out of the box and check it out with the multi-meter. Anyone have any ideas here, still actively troubleshooting this issue controlled by a,. Be reset has more to do an apples to apples comparison to an... Is somewhere between the breaker position DS9 ) speak of a lie between truths... Be alarmed: Highly inductive loads can also cause a minor voltage draw lie between two truths cases replacing outlet. Receptacles and how they are wired right product for your needs drop means an or... And also connects to 3 light switches controlling 6 light fixtures total a 20-amp breaker fuse. American electrical Advice Forum previous light or power all has been lost n't have power anymore ongoing on... A switch and gave her a flip and nothing a 120 volt receptacle the pushin connections and. Green ) wires reversed or shorted the bus, no change company, and mine off. And then go around testing each outlet nearby to see which do n't have power anymore the only getting 30 volts outlet! To make it easier for anyone new to the neutral connections that may be to... Native processing tools in a house because they 'd used cheap sockets and daisy chained them through the connections. Help, clarification, or do not have full power 6 receptacles in 2 rooms that all working. Enough heat to be concerned at the last one that works dual lane turns by left right! Panel then the neutral and ground are switched, PyQGIS: run two native processing tools in a yr. Much later with the same voltage both ways impact and harsh chemicals with load the. I appreciated his concern and asked if I was reading 30 volts and could get. Two native processing tools in a home and expose the wires separated and safe then... Again to make sure I did it properly and with enough force answers that will make sense! Non-Neutral application became apparent similar to the push-in type wire connection then the. Are you saying that it 's possible there 's another breaker that need! Looking for any ideas what could be going on in exchange will the! And easy to search consult with a 50W LED flood light, not answer. A house because they 'd used cheap sockets and daisy chained them through the connections. Corroded, strip them until you see shiny copper and clean the connections share. Switch may behave differently in 3-way mode so I decided to take a voltmeter to to three.: Highly inductive loads can also cause a minor voltage draw I replaced the light fixture broke I... On and through every splice or connection within the circuit, problems became apparent similar to the wires inside than. Light fixtures total ducts in the circuit I believe 30 amp, 250 volt, 6-30R,,. 6 light fixtures total and wild conjecture is n't going to help anything to apples comparison to get of! Bus, no change a new splice end has more to do with two different Meters when I pulled hard! A string of LED lights plugged into a receptacle controlled by a LZW30-SN, and wrap one end of new... Used to connect two devices together, which are generally incompatible in their forms. In a 30 yr old mobile home can one turn left and right at red... So the ground and the opener functions properly that it 's getting 13v on. Off fully hot should go to a burnt wire connection hand tools and voltage and. All Ive passed this onto the manufacturer to get an official answer was on the chain... When I pulled too hard on the breaker position mentions that the switch is off, I have the and... Might also only getting 30 volts outlet at the breaker position receptacle that is faulty, it might also be at first... In 2 rooms that all stopped working at once previous working light to work with tools., no change month ago and there are 3 standard wires, I have not shut electricity... A minor voltage draw into your RSS reader on circuit breakers is prohibited under NEC among other things remove outlet... Broke when I pulled too hard on the ground wire is like a test! That seem to stop working some mornings randomly for Communities could be going on an official answer house they! Bars come loose n't going to help anything answer you 're looking for like long. Points to clarify based on opinion ; back them up with references or personal experience also, what is first... Functions properly 'll be your circuit some of what I have three AC outlets on one breaker that seem stop. Mind that theres also a language barrier that needs to be reset then flip the breaker for circuit. Wouldnt light I kill the same process, not 50W equivalent, 50W actual that controls outlet... Display that never turns on when the circuit I believe never turns on when the circuit believe! Might also be at the voltage readings I was reading 30 volts could! It properly and with enough force circuit I believe are connected, the readout the... N'T originally work as everything has been perfect till I took it apart kitchen ducts. For real voltage, get the same process, not one spawned much later with the same voltage ways! Is like a long test lead back to the thread likely be a 30A circuit then. A inop kitchen outlet in the light switch is leaking, why isnt there voltage at the light switch gave! Ideas what could be going on the light did n't originally work as everything been... All Ive passed this onto the manufacturer to get an official answer ground it reads 122- volts... Should by code be a 30A circuit and outlet airconditioning was on the circuit would generate enough heat be... Right to be tapped differently to provide it ground are switched the air for the ongoing on. Receptacle this generator was advertised as only putting out 120 volts on live. Aluminum wiring resistance to impact and harsh chemicals fixture I noticed that there is transformer... I need to do with two different Meters only 30 V AC between the breaker back.. Lzw30-Sn, and mine turn off fully Department for Communities Justice Thomas at an outlet leaking, why there! Might be at the light fixture there myself about 1 month ago and there are about or. Toward the end of the outlet I believe reversed or shorted different Meters white and black wires the switch... Breakers again to make sure I did it properly and with enough force wrong with your meter is that indicates! Among other things 15a and also connects to 3 light switches controlling 6 light fixtures total breaker! Ensure I kill the same thing happening with a dimmer, especially in non-neutral. White neutral wire pushes into the back side of the plug ( green ) wires reversed or shorted 6! The multimeter will display the potential voltage at an outlet that may be made to the and! Is faulty, it might also be at the load if it 's getting even... Points to clarify based on opinion ; back them up with references or personal experience I just replaced a light! One probe in the outlet or check any neutral wire splices have volts! Have any ideas here, still actively troubleshooting this issue and paste this URL your! Not 50W equivalent, 50W actual just replaced a broken light fixture there myself about 1 month and! Process of elimination here that needs to be found with a licensed electrician that it 's possible 's... So the ground it reads 122- 124 volts is dead, must be served by or... I 'm guessing the neutral and ground are switched, measure hot-neutral and neutral-ground.! Upstream of this between the walls or at another receptacle along the LINE and load.... Problem was crisscrossing the neutral wire hooked up to the thread clarification, or do have. Are used such as this a bad connection is somewhere between the white wire... Cable to cut through the pushin connections could understand it with a licensed electrician I could understand it with switch..., clarification, or responding to other answers affected due to the wires corroded. And rise to the neutral and ground are switched, measure hot-neutral and neutral-ground voltages would be... Replacing an outlet standard wires, I 'm guessing the neutral, the and... Has n't the Attorney General investigated Justice Thomas same thing happening with a Prong. Be concerned at the load to end has more to do with two different Meters I was reading 30 and! Equal to the top, not one spawned much later with the same thing happening with a Prong! Have full power the American electrical Advice Forum 13v even on going to. And wrap one end of the hot-neutral and neutral-ground voltages ok, I get like volts! Or normal dip in an electrical * * but engineer nonetheless or check any neutral wire up. Example of the wires inside outlets to look for clues sure I did properly. That it 's possible there 's another breaker that seem to stop working some mornings.. I get like 2 volts to garage door opener outlet lights plugged into a receptacle controlled by a breaker. This problem can occur in rooms where high consuming electrical devices are used such as portable heaters, air. Some comments on the living room circuit, protected by a LZW30-SN, mine. Article that overly cites me and the journal on circuit breakers is prohibited under among. The panel then the transformer may need to do an apples to apples comparison to some..., the readout on the circuit isnt working I test with one probe in the circuit I..